Skip to content
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension


Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
22 changes: 22 additions & 0 deletions .github/workflows/ci.yml
Original file line number Diff line number Diff line change
@@ -0,0 +1,22 @@
name: Validate package

on:
push:
pull_request:

permissions:
contents: read

jobs:
test:
runs-on: ubuntu-latest
strategy:
matrix:
python-version: ["3.10", "3.12"]
steps:
- uses: actions/checkout@v4
- uses: actions/setup-python@v5
with:
python-version: ${{ matrix.python-version }}
- name: Validate SetupHelper package and safety defaults
run: ./tools/validate-package.sh
12 changes: 12 additions & 0 deletions .gitignore
Original file line number Diff line number Diff line change
@@ -0,0 +1,12 @@
__pycache__/
*.py[cod]
*.egg-info/
.pytest_cache/
.DS_Store
._*
build/
dist/
*.tgz
*.sha256
startup.log
state/
16 changes: 16 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,16 @@
# Changelog

## v0.5.0b4 - initial SetupHelper candidate

- Import the exact `0.5.0-rc4` source currently deployed on the Foretravel
Cerbo GX.
- Add a SetupHelper-compatible service package named `rvforefish`.
- Store configuration and generator ownership state outside the downloaded
package so updates cannot silently replace safety settings.
- Ship a fail-closed default: monitor-only, no RV-C transmission, no control
features, no source-label writes, and no automatic current-limit changes.
- Refuse to replace an existing manually managed `foretravel-rvc` service.
- Preserve an explicit, non-destructive migration path from the legacy
`/data/apps/foretravel-rvc` deployment.
- Restrict the initial package to the tested Venus OS v3.75 baseline.
- Add automated package checks and the full 144-test replay/unit suite.
210 changes: 210 additions & 0 deletions README.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,210 @@
# Foretravel SilverLeaf RV-C integration

Safety-gated integration of the 2006 Foretravel Phenix SilverLeaf TM-102 with
Victron Venus OS on a Cerbo GX Mk2.

> [!CAUTION]
> This is vehicle-control software developed against one specific coach. The
> SetupHelper package ships fail-closed and read-only. Do not enable an RV-C
> command or Victron write gate merely because the package installed.

The project has four separate responsibilities:

1. Decode authoritative TM-102 RV-C status for the generator, its complete
read-only AGS/START configuration, water pump, autofill, tanks, ambient
temperatures, and AC source.
2. Publish native Venus telemetry without creating a second generator owner.
3. Offer explicitly enabled, feedback-verified pump, autofill, and cooperative
generator-demand controls in the Venus switch pane.
4. Classify shore, generator, and inverter operation conservatively so the UI
never labels an unaccepted or merely requested source as active.

## Current safety posture

- Imported application source: **0.5.0-rc4**, byte-for-byte matched to the
deployed Cerbo source before publication.
- Offline validation: **144 replay and unit tests passing**.
- Package default: **monitor-only** with no CAN transmission.
- Control features: **all disabled** in `config.default.json`.
- Victron writes: **source relabeling and automatic current-limit changes are
disabled** in the package default.
- Operational configuration: stored in `/data/rvforefish-data/config.json`,
outside the GitHub-managed package so an update cannot replace it.
- Live Cerbo: **not changed by publishing or downloading this repository**.

The public package default is completely read-only: it does not transmit RV-C,
relabel the AC source, change the input current limit, write DVCC/AGS, or
operate physical relays. An existing coach configuration may contain an
attended and separately approved temporary source-label/current-limit
heuristic; that operational configuration is deliberately not shipped by this
repository and is never substituted during an update.

The first live projection matched the captured coach state: pump on, autofill
off, generator stopped, no generator demand, and 75,495 runtime minutes. The
generator service contains no remote-start paths and Venus created no
`com.victronenergy.generator.*` control owner.

The current 0.5.0-rc4 worktree candidate passes 144 offline tests. Its first
deployed 0.1 resource sample used 6
CPU ticks in 10 seconds (about 0.6% of one core), 16 MiB RSS, an 8 KiB bounded
log, and 328 KiB of application storage. A direct monitor-only D-Bus write was
rejected and the switch State remained unchanged.

The 2026-08-10 Cerbo installation passed on-device configuration preflight,
started alongside stock `dbus-rv-c.vecan0`, and retained rollback backup
`/data/apps/foretravel-rvc-backup-20260810-220536`. Post-install checks found
zero `AUDIT TX` records, zero new service errors, no generator-control D-Bus
owner, hidden controls, generator stopped with no demand, both Ruuvi services
present, and AggregateBatteries connected with all four batteries online.

The 2026-08-11 rc3 installation also passed on-device monitor-only preflight
and retained rollback backup
`/data/apps/foretravel-rvc-backup-20260811-002150`. Its post-install audit
found the generator stopped with all demand classes false, no ownership marker,
Grid/30 A, four online and zero stale BLE batteries, AggregateBatteries still
selected for BMS control, three Ruuvi services, stock RV-C up, Signal K down,
and zero live vecan0 error counters.

Version 0.3.0 additionally understands all eleven fixed TM-102 AGS criterion
instances, current and legacy criterion counters, generator starter timing,
standard AGS safety configuration, and proprietary stop-policy reports. Every
one of those paths is read-only. Because the criteria normally report only on
request, they populate after the Total Coach START pages request them; the
bridge never transmits a configuration query while monitor-only.

Version 0.4.0 corrected tank percentage scaling to use the transmitted
resolution, decodes complete pump/autofill status plus the documented TM-102
configuration reports, and publishes explicit stale/result/interlock
diagnostics. Autofill start requires fresh pump, fill, and fresh-tank
status; a valid nonzero TM-102 timeout; the configured pressure/hookup policy;
and an explicit secondary bridge maximum run time. Stop works with stale
status, and a persistent cleanup marker causes an unclean restart to send a
fail-safe stop until the TM-102 actually reports Off.

Generator demand uses the same marker-before-TX ordering. Release is retried,
and its marker remains until fresh Network Demand status proves False; a
stale marker with release TX unarmed makes startup fail closed. Version
0.5.0 adds RV-C priority-6 cooperative demand using
`01FCFFFFFFFFFFFF` for demand and `00FCFFFFFFFFFFFF` for release. It does not
copy the Total Coach panel's `5D/5C` manual-override frames. Both VE.Bus input
leg currents must remain below a configured threshold continuously, followed
by a full five-minute unloaded cooldown, before a normal release. Live
orphan-demand and Cerbo-power-loss testing remains mandatory before the
generator feature gate can be enabled.

The first attended network-demand start proved that `0xE2` and
`01FCFFFFFFFFFFFF` were accepted by the TM-102 without setting manual
override. It also exposed a start-state race: a repeated pre-crank Stopped
status triggered an early fail-safe Release even though the generator was
starting normally. 0.5.0-rc2 retains demand through those Stopped repeats
until Running, Fault, or the bounded 120-second start timeout.

The rc2 orphan-process test then proved that Overall Demand can be false while
Network Demand remains true after a Cerbo reboot. rc3 retains the cleanup
marker in that state and sends a source-specific Release once stopped/faulted;
Network Demand false is the authoritative proof that this network category has
cleared. The rc3 retest passed process-loss recovery, but it also corrected
the interpretation of every previous five-minute run: the TM-102 stopped just
before the bridge Release, not because of it. rc4 therefore reasserts the same
cooperative `01FC...` demand every 60 seconds while ownership remains active,
including through unload/cooldown and after fresh process recovery. Persistent
generator TX remains gated until a live run stays active beyond five minutes
and then stops only after the bridge's `00FC...` Release.

The candidate also preserves the deployed temporary source classifier and
publishes the stricter ATS-based classification as a diagnostic. The
temporary classifier is explicitly identified as a heuristic and is not
silently promoted to an authoritative ATS signal.

## Verified captures

| Fixture | Frames | Evidence |
|---|---:|---|
| `rvc-baseline.can` | 1,840 | Pump on, autofill off, no generator demand, generator stopped, runtime 75,495 minutes |
| `rvc-shore-passive.can` | 914 | AC present at VE.Bus, but no TM-102 ATS or generator AC frames in 15 seconds |
| live 2026-08-08 cycle | n/a | Panel start `5D...`/stop `5C...`; TM-102 demand and run/stop feedback; guarded Generator/50 A and Grid/30 A transitions |

The coach still does not publish an authoritative ATS source. The approved
60-second/two-leg heuristic therefore remains a bounded shortcut; a dedicated
transfer-source signal is still the long-term upgrade.

## SetupHelper package

The repository root follows the SetupHelper/PackageManager package contract:

- `version` is the SetupHelper package version.
- `gitHubInfo` identifies the GitHub owner and development branch.
- `setup` installs or removes the `foretravel-rvc` runit service.
- `services/foretravel-rvc` contains the service and bounded log definition.
- `config.default.json` is copied only when no persistent configuration exists.
- `validFirmwareVersions` restricts the initial candidate to the tested Venus
OS v3.75 baseline.

Use a pinned release tag in PackageManager. Do not configure this control
package to automatically follow `main` or `latest`.

### Existing manual deployment

The SetupHelper installer deliberately refuses to replace the current
`/data/apps/foretravel-rvc` service. Migration is an attended operation:

1. Download the package but do not install it.
2. Run `/data/rvforefish/tools/import-legacy-config.sh`.
3. Review `/data/rvforefish-data/config.json`, especially every write/control
gate.
4. Confirm the generator is stopped and no generator-demand ownership marker
exists.
5. Disable the legacy service with
`/data/apps/foretravel-rvc/disable.sh`.
6. Install the pinned package from PackageManager.
7. Verify service state, CAN errors, D-Bus ownership, battery aggregation, and
Ruuvi reporting before declaring the migration complete.

The legacy application directory is retained as the rollback target. The
package refuses uninstall while it has a generator-demand ownership marker.

## Run the replay and package tests

```sh
./tools/validate-package.sh
```

## Monitor-only service

```sh
svstat /service/foretravel-rvc
tail -n 100 /var/log/foretravel-rvc/current | tai64nlocal
dbus -y com.victronenergy.genset.socketcan_vecan0_di40_ucFA / GetItems
dbus -y com.victronenergy.switch.foretravel_rvc / GetItems
```

Start the read-only 24-hour safety/resource soak:

```sh
nohup /data/apps/foretravel-rvc/tools/soak-audit.sh 300 288 \
> /data/log/foretravel-rvc-soak.stdout 2>&1 &
```

For a migrated system, package rollback is intentionally attended:

```sh
/data/rvforefish/setup uninstall
/data/apps/foretravel-rvc/enable.sh
```

Do not perform that rollback while generator demand is owned or while an
attended control operation is in progress.

## Documentation

- [Requirements and acceptance gates](docs/requirements.md)
- [Evidence register](docs/evidence-register.md)
- [RV-C DGN matrix](docs/dgn-matrix.md)
- [SilverLeaf function inventory and ownership](docs/function-inventory.md)
- [Architecture and ownership model](docs/architecture.md)
- [Risk register](docs/risk-register.md)
- [Deployment and validation plan](docs/deployment-and-test-plan.md)
- [0.5.0-rc1 safety and release audit](docs/release-0.5.0-rc1-audit.md)
- [0.5.0-rc2 commissioning regression audit](docs/release-0.5.0-rc2-audit.md)
- [0.5.0-rc3 orphan-demand recovery audit](docs/release-0.5.0-rc3-audit.md)
- [0.5.0-rc4 TM-102 demand keepalive audit](docs/release-0.5.0-rc4-audit.md)
31 changes: 31 additions & 0 deletions config.default.json
Original file line number Diff line number Diff line change
@@ -0,0 +1,31 @@
{
"interface": "vecan0",
"tm102_source": 250,
"source_address": null,
"monitor_only": true,
"genset_device_instance": 40,
"switch_device_instance": 50,
"temperature_device_instance_base": 60,
"features": {
"water_pump": {"enabled": false, "payload_validated": false},
"autofill_stop": {"enabled": false, "payload_validated": false},
"autofill_start": {"enabled": false, "payload_validated": false},
"generator_demand": {"enabled": false, "payload_validated": false}
},
"generator_orphan_demand_test_passed": false,
"generator_unload_test_passed": false,
"autofill_interlocks_verified": false,
"source_label_writes": false,
"authoritative_source_signal_verified": false,
"ack_timeout_seconds": 2.0,
"max_retries": 2,
"status_max_age_seconds": 7.0,
"generator_cooldown_seconds": 300.0,
"generator_keepalive_seconds": 60.0,
"generator_start_timeout_seconds": 120.0,
"generator_max_run_seconds": null,
"generator_unloaded_current_threshold_amps": null,
"generator_unloaded_confirm_seconds": 30.0,
"generator_stop_escalation_seconds": null,
"autofill_max_run_seconds": null
}
Loading