Skip to content

About

No description, website, or topics provided.

Resources

Contributing

Stars

0 stars

Watchers

0 watching

Forks

Repository files navigation

blaueis-hvacshark

Part of the Blaueis project umbrella. Protocol library and gateway code lives in blaueis-libmidea. Capture sessions live in blaueis-hvacshark-traces.

Blaueis is a small glacier in the Bavarian Alps, retreating year by year. Use energy responsibly — climate change is real.

Open-source protocol research toolkit for HVAC and heat pump systems. Captures, decodes, and dissects the internal communication buses of air conditioning and heat pump units to build open, well-documented knowledge of how these systems communicate — enabling better user experiences and advanced integrations: Home Assistant automations, PV-optimised operation, improved eco-friendliness, and more.

Multi-manufacturer and multi-protocol by design: the same physical interface may carry different data protocols across device models or generations, and the project treats each such variant as a distinct protocol. Currently focused on the Midea/Carrier family, with the architecture ready for additional manufacturers.

Disclaimer and intended use

This code is provided for research and educational purposes only. There is absolutely no warranty that it works as intended. Use of this code should not encourage anyone to work on their HVAC systems, as doing so carries risks of personal injury or property damage. The author is not responsible for any harm or damage resulting from the use of this code.

Brand names and trademarks: Any manufacturer, product, or model names mentioned in this repository are used solely to identify the hardware under test. Their use is purely descriptive — to specify which physical device was captured — and does not imply affiliation, endorsement, or any commercial relationship with the respective trademark holders. All trademarks remain the property of their respective owners.

This repository aggregates publicly available information for research and debugging purposes. If you have concerns about brand name usage or attribution, please open an issue or contact the author directly.

Components

Component Path Description
Wireshark Lua dissectors tools/dissector/ Dissects HVAC_shark UDP frames in Wireshark (one per manufacturer family)
ESP32 / Python dongle tools/dongle/mid-xye/ Live-capture firmware + Python serial-to-UDP bridge
Protocol documentation protocols/<manufacturer>/ Protocol documentation organised into spec/, devices/, analysis/

Currently supported protocols

  • mid-xye — Midea XYE RS-485 inter-unit bus (4800 baud, 16/32-byte frames)
    • Includes UART (WiFi module ↔ mainboard), R/T (indoor ↔ outdoor extension board), Display–Mainboard internal bus, and IR remote protocols

Repository layout

tools/
  dissector/            Lua dissectors loaded into Wireshark (one per manufacturer family)
  dongle/mid-xye/       ESP32 firmware + Python serial-to-UDP bridge
    mid_xye/            Arduino project (PlatformIO)
    py-mid-xye/         Python equivalent bridge
protocols/
  midea/                Midea family protocols
    spec/               Protocol specifications (UART, R/T, XYE, IR, Display-Mainboard)
    devices/            Device-specific behaviour documentation
    analysis/           Special function deep-dives

Companion repository: blaueis-hvacshark-traces

Capture sessions, raw logic-analyser exports, and session documentation live in a separate repository to keep binary data out of the main codebase:

blaueis-hvacshark-traces

Contents:

  • .pcap files converted from Saleae logic-analyser exports, ready to open in Wireshark
  • Raw Saleae CSV exports and .sal session files
  • SessionNotes.md (operator logs) and findings.md (analysis results) per session
  • channels.yaml configuration files used by the offline pcap converter

Each device has its own subfolder (e.g. Midea-extremeSaveBlue-display/) with a README describing the hardware, captured buses, and session index.

The offline pcap converter (logicanalyzer-tools/logic_analyzer_midea_to_pcap.py) lives in the dumps repository next to the data it processes.

Conventions

  • Temperature: all temperature values are in °C (Celsius) unless explicitly noted otherwise in the relevant file or field description.

AI-assisted research

This project doubles as an experiment in using AI tools to consolidate scattered protocol research — multiple codebases, forum posts, hardware captures — into a single cross-referenced protocol reference. All protocol knowledge traces back to community work or own captures; AI assists with organisation and validation.

Contributing

Contributions are welcome. See CONTRIBUTING.md — covers the citation rule, confidence-label conventions, where new protocol / device / analysis content belongs, and what good PRs look like. For anything non-trivial (new protocol, new manufacturer, new device family), open an issue first.

Acknowledgements

A huge thank you to the open-source and home-automation community — especially the contributors around Home Assistant, ESPHome, and the broader maker community — for their tireless research work and for publishing their findings openly.

Projects that made this research possible:

Related projects in this ecosystem

If you believe your work is referenced here without proper attribution, if you would like code or findings removed, or if you have any licensing concerns, please open an issue or get in touch directly via this GitHub repository. We will respond promptly.

For AI agents

AI agents working in this repository should follow the instructions in AGENTS.md. Unless otherwise advised by the repository owner, AGENTS.md is the authoritative guide for coding style, working conventions, protocol documentation standards, and confidence labelling.