Configuration Reference: Elero ESPHome Component

Complete reference for all YAML-configurable parameters.

Requires ESPHome 2026.9.0 or newer, with ESP32 using ESP-IDF or Arduino. See ESPHome compatibility for native API lifecycle details.

Heads up — devices are no longer YAML-defined. Since v0.11.0 (RFC-002), cover: - platform: elero and light: - platform: elero are gone. All blinds and lights live in NVS and are managed through the web UI. See MIGRATION-yaml-to-nvs.md if you're upgrading.

What stays in YAML: the radio hub, the output adapter (elero_nvs: or elero_mqtt:), and the web UI.


Hub: elero

The central hub controls SPI communication with the radio module. Three radios are supported:

Radio Chip Interface Status
cc1101 TI CC1101 Register-based SPI Stable (default)
sx1262 Semtech SX1262 Command-based SPI Experimental
sx1276 Semtech SX1276/77/78 Register-based SPI Experimental

Common Parameters

Parameter Type Required Default Description
radio String No cc1101 Radio driver: cc1101, sx1262, or sx1276
cs_pin GPIO pin Yes - SPI chip select pin
irq_pin GPIO pin (input) Yes - Interrupt pin (GDO0 for CC1101, DIO1 for SX1262, DIO0 for SX1276)
gdo0_pin GPIO pin (input) - - Deprecated alias for irq_pin (CC1101 backward compatibility)
freq0 Hex (0x00-0xFF) No 0x7a CC1101-format frequency register FREQ0
freq1 Hex (0x00-0xFF) No 0x71 CC1101-format frequency register FREQ1
freq2 Hex (0x00-0xFF) No 0x21 CC1101-format frequency register FREQ2

The hub extends the ESPHome SPI configuration. spi: must be configured separately with clk_pin, mosi_pin, and miso_pin.

CC1101 Configuration

elero:
  cs_pin: GPIO5
  gdo0_pin: GPIO26

No additional parameters required. The CC1101 is the default radio.

SX1262 Configuration

Parameter Type Required Default Description
busy_pin GPIO pin (input) Yes - SX1262 BUSY pin
rst_pin GPIO pin (output) Yes - SX1262 reset pin
fem_pa_pin GPIO pin (output) No - External PA enable pin (e.g. Heltec V4 GPIO46)
rf_switch Boolean No false Use DIO2 as RF switch control
pa_power Integer (-3 to 22) No 22 TX output power in dBm
tcxo_voltage Float (1.6-3.3) No - TCXO voltage via DIO3 (omit if using crystal)
elero:
  radio: sx1262
  cs_pin: GPIO8
  irq_pin: GPIO14      # DIO1
  busy_pin: GPIO13
  rst_pin: GPIO12
  rf_switch: true
  tcxo_voltage: 1.8

SX1276 Configuration

Parameter Type Required Default Description
rst_pin GPIO pin (output) Yes - SX1276 reset pin
pa_power Integer (-1 to 20) No 17 TX output power in dBm
elero:
  radio: sx1276
  cs_pin: GPIO18
  irq_pin: GPIO26      # DIO0
  rst_pin: GPIO23
  pa_power: 17

Frequency Variants

Variant freq0 freq1 freq2 Notes
Standard 868 MHz 0x7a 0x71 0x21 Default setting
Alternative 868 MHz 0xc0 0x71 0x21 Most common alternative

Adding devices (no YAML)

Devices live in NVS. Pick exactly one of the two output adapters below (elero_nvs: for native ESPHome API, elero_mqtt: for MQTT discovery), flash, then add devices through the web UI:

  1. Open http://<device-ip>/elero.
  2. Press a button on a physical Elero remote — it auto-appears in the UI.
  3. Click Save to persist the discovered cover/light to NVS.
  4. (Optional) Hub → Backup & Restore → Download backup. Keep the JSON safe for chip-swap recovery.

To restore from a backup (or migrate from older YAML): Hub → Backup & Restore → Restore from backup.

Per-device fields managed in the UI

These are stored in NvsDeviceConfig (see components/elero/nvs_config.h) and edited via the web UI's device editor. Fields marked (cover) and (light) apply to that device type only.

Field Type Default Description
dst_address Hex (24-bit) required RF address of the blind/light
src_address Hex (24-bit) required Emulated remote address
channel Integer (0-255) required RF channel
name String (≤23 chars) empty Display name in HA
enabled Boolean true Whether the device is published to HA
open_duration_ms Integer 0 (cover) Travel time fully open. 0 = no position tracking.
close_duration_ms Integer 0 (cover) Travel time fully closed. Pair with open_duration_ms.
movement_mode standard / step standard (cover) Step mode makes Open/Close use targeted continuous travel.
supports_tilt Boolean false (cover) Enable HA tilt controls. No measured slat angle is available.
tilt_mode preset / step preset (cover) HA tilt controls recall the saved preset, or send directional short presses. Independent of movement_mode.
command_up Hex byte 0x20 (cover) Full opening command
command_down Hex byte 0x40 (cover) Full closing command
command_stop Hex byte 0x10 (cover) Stop command
command_check Hex byte 0x00 (cover) Status query command
command_tilt Hex byte 0x24 (cover) Saved tilt command
ha_device_class Enum shutter (cover) shutter/blind/awning/curtain/shade/garage
dim_duration_ms Integer 0 (light) Dimming travel. 0 = on/off only.
hop Hex byte 0x0a Protocol hop counter
payload_1 Hex byte 0x00 Protocol payload byte 1
payload_2 Hex byte 0x04 Protocol payload byte 2
msg_type Hex byte 0x6a Message type (0x6a = command)
type2 Hex byte 0x00 Secondary type byte

The protocol bytes (hop, payload_*, msg_type, type2) are rarely overridden — defaults match every Elero motor seen in the wild. Only touch them if you've sniffed an unusual remote and confirmed it differs.

Step receiver movement mode

Set movement_mode to step for a receiver whose ordinary UP/DOWN commands only make short movements. The cover editor calls this Step receiver. Save the device to apply the mode. It applies to normal Open/Close commands from all adapters, calibrated position commands, and saved groups.

Action Wire command Packet type / destination
Open in step mode, or explicit full_up 0x21 0x6a, the cover's 24-bit receiver address
Close in step mode, or explicit full_down 0x41 0x6a, the cover's 24-bit receiver address
Explicit step_up 0x20, then release 0x00 0x44, the paired remote channel
Explicit step_down 0x40, then release 0x00 0x44, the paired remote channel
Saved tilt / intermediate preset command_tilt / 0x44 Existing channel-button path
Stop / status query command_stop / command_check Existing receiver-addressed path

Full-travel packets use type2=0x10, hop=0x00, as in the captured long-press transactions. Each full-travel action uses the existing three-packet repetition and follow-up CHECK. A short step uses three press packets followed by three release packets with the existing 10 ms repeat interval. Both phases are reserved before the step is accepted, so a full queue cannot accept only a press. This is a short pulse, not a reproduction of every remote's hold duration. Official MonoTel 2, VarioTel 2, and TempoTel 2 manuals describe the physical jog/pulse feature, with receiver-dependent results. They do not define these RF bytes or repeat/release timings. See official manual evidence for the exact pages and source hashes.

Step mode takes precedence over command_up and command_down; those custom values are retained and become active again in standard mode. In standard mode, UP/DOWN overrides that resolve to 0x21 or 0x41 also use targeted full-travel packets. Other custom commands keep their existing packet format. Explicit full_up/full_down and step_up/step_down bypass the UP/DOWN overrides.

Both native API and MQTT discovery expose four Home Assistant buttons for each enabled cover: Short press up/down and Full up/down. Button presses use the same registry action dispatch as WebSocket cmd and the MQTT cover command topic. No adapter selects packet bytes, estimates positions, or maintains a button state. The public action IDs remain step_up, step_down, full_up, and full_down; “short press” describes the transmitted action without promising a fixed movement distance.

Native API registers the buttons at boot with stable address/action identities and names that remain valid for the firmware lifetime. After device changes, follow the native mode reboot prompt to update entity registration. Existing buttons resolve their cover through the registry on each press; disabled or removed covers are rejected even before a reboot. A reused registry slot does not change which cover an existing button controls.

MQTT publishes retained button discovery configs under the same HA device as the cover, with the gateway's availability topic. Each button uses the existing cover /set subscription and its canonical action as payload_press. Commands are not retained. Rename and reconnect retain stable discovery identities; disable/remove clears all four button configs. Startup cleanup includes the button domain and removes only stale discovery owned by this gateway.

The explicit actions are also available directly through WebSocket cmd and the MQTT cover command topic. Step actions apply to one configured cover at a time; the RF channel can still contain several paired receivers. On standard roller shutter receivers, even a short press can start full travel. Test the actual receiver.

Groups containing full-travel actions send one targeted command per receiver; they do not encode those commands as a multi-selector 0x44 packet. Group start times are therefore not guaranteed to be simultaneous.

An accepted manual movement, preset, or short press replaces any earlier timed position target. A rejected command leaves the existing target unchanged. Status queries do not replace a movement plan.

enabled controls publication to Home Assistant. Manual web controls remain available for unpublished covers, including STOP. Disabling a cover cancels its pending commands. Explicit cover commands requested afterward can still drain, while background polling and automatic timers remain disabled. Percentage-position requests are ignored while the cover is unpublished; use explicit directions or STOP instead. Native action buttons reject unpublished movement actions through the registry, even before a reboot.

The mode uses a previously unused flag bit. The NVS record stays at 64 bytes, with the same version and field offsets. Export/import includes movement_mode; old backups without it restore standard mode. Older firmware ignores the new mode and uses its original movement handling. No new angle or position feedback is inferred. See hardware testing.

Cover position and tilt

For percentage positioning, expand a cover in the Devices tab and enter its measured full opening and closing travel times in seconds (the up/down fields). Both must be greater than zero. The firmware stores these as open_duration_ms and close_duration_ms, estimates position from elapsed travel time, and sends STOP when an intermediate target is reached. Use a full travel to a confirmed endpoint to establish a reference; intermediate positions remain estimates and can drift. Do not use placeholder travel times just to enable a slider.

In MQTT mode, saving these values updates discovery and republishes known state without moving the cover. In native API mode, reboot after changing capabilities so Home Assistant receives the updated entity information. A HomeKit bridge can cache accessory capabilities: after verifying current_position and position control in HA, use HA's homekit.reset_accessory for only the affected cover if Apple Home still has the old controls. Resetting an accessory can require restoring its Apple Home room, name, scenes and automations; do not reset the entire bridge.

supports_tilt enables HA's tilt controls. Choose the behavior with tilt_mode:

  • preset (default): every valid HA tilt request recalls the saved tilt preset (command_tilt, normally 0x24). Existing devices and backups keep this mode.
  • step: each HA tilt request below 50% sends one short DOWN press; 50% or above sends one short UP press. The common registry uses the existing three press packets plus three release packets. Full-travel mode and custom command bytes do not change these short presses.

Neither mode sets or measures an absolute angle. RF-reported tilt state remains the existing binary saved-preset status; short presses do not manufacture an angle or lift-position estimate. Use the HA tilt-open/tilt-close controls for directional steps. Intermediate percentages select a direction, not a target angle. Invalid, non-finite, or out-of-range targets are rejected before enqueue.

Select HA tilt control in the expanded web settings and Save to NVS. The Tilt toggle must be enabled. The setting is independent of Open/Close movement mode; the separate tilt action and Saved tilt shortcut always recall the preset. Short presses address the paired channel, so other covers on that channel can respond. A standard roller shutter can travel fully after a short press. Use directional mode only with a receiver that has the required short-press behavior.

Native API and MQTT normalize their targets and use the same registry route. The shared sender serves CC1101, SX1262, and SX1276. No radio-specific tilt path is used. NVS record size/version and backup snapshot version stay unchanged.

Cover state topics are retained at the MQTT broker so a restarted HA or a new discovery subscription receives the last reported state. The gateway's availability topic still marks covers unavailable when it disconnects. Removing or disabling a cover clears its retained state, and removing position/tilt support clears the corresponding retained values. At gateway startup, old retained cover state is cleared until the motor is observed again; no initial 50% position is advertised.


Web UI: elero_web

Cover command bytes are optional and also round-trip through device CRUD and backup JSON. Open Custom command bytes in a cover's expanded settings to edit Open, Close, Stop, Status query, and Saved tilt. The editor accepts one or two hex digits, with an optional 0x prefix, and formats them as 0x00–0xFF. Invalid input keeps the previous value and shows an error. Use Save to NVS to apply changes. Reset command bytes restores the five defaults and also requires Save. These fields are available only for covers and require CRUD support. They do not change the explicit Short press or Full travel buttons.

Step receiver mode takes precedence over custom Open and Close bytes. Select Standard mode to use those overrides; switching modes keeps their stored values.

For Raffstore variants, set command_up to "0x21" and command_down to "0x44" when those values match the physical transmitter. Legacy NVS records ignore the repurposed reserved bytes; old backups use the default commands. The 64-byte NVS record and version remain unchanged.

Saved groups contain stable member addresses and survive removal of members until the last member is removed. Group position is the average of member positions. Any moving member makes the group moving (opening takes precedence if members move in opposing directions); every cover must have opening and closing durations before group position control is offered. Disabled members make their group unavailable without deleting its saved membership. MQTT group updates apply immediately. Reboot after you change a native group. Both modes expose saved light groups with an on/off control. The group shows ON if at least one member is on.

Members sharing a remote and command variant use one 0x44 selector-list transmission; different remotes or command variants use their own TX paths. Group state is published through MQTT and group_state_changed WebSocket events, and is included in the initial WebSocket config.

Web interface for device CRUD, RF discovery, backup/restore, and live RF/log tailing. Accessible at http://<device-ip>/elero.

# web_server_base is automatically loaded by elero_web.
# Declare it explicitly to configure the port:
web_server_base:
  port: 80

elero_web:

Prerequisites:

  • web_server_base is automatically loaded by elero_web. Do not use web_server: -- that re-enables the default ESPHome UI at /. Navigating to / will redirect automatically to /elero.

Features:

  • Devices tab — add, edit, remove blinds/lights/remotes.
  • Hub tab — display name override, read-only radio frequency with advanced diagnostics, raw TX, Backup & Restore. Set freq0, freq1, and freq2 in YAML, then rebuild and flash to change the radio frequency.
  • Packets tab — live RF traffic.
  • Logs — ESPHome elero.* logs in real time.

WebSocket protocol

The web UI talks to the device over WebSocket at /elero/ws. The full protocol is documented as an AsyncAPI spec at components/elero_web/frontend/app/asyncapi.yaml — that file is the authoritative source.

Endpoint Description
/ Redirect to /elero
/elero Web UI (HTML, served gzipped)
/elero/ws WebSocket for real-time communication

Server → client events include config, rf, log, device_upserted, device_removed, state_changed, group_upserted, group_removed, group_state_changed, hub_config, config_snapshot, import_result, error. Client → server messages include cmd, raw, upsert_device, remove_device, upsert_group, remove_group, group_cmd, set_hub_config, export_config, import_config, restart.

Why Mongoose? ESPHome ships different HTTP backends per framework (Arduino vs ESP-IDF). Mongoose provides one API for both.


Platform: switch (Web UI Control)

Optional runtime control to enable/disable the web UI. When disabled, all /elero endpoints respond with HTTP 503.

switch:
  - platform: elero_web
    name: "Elero Web UI"
    id: elero_web_switch
    restore_mode: RESTORE_DEFAULT_ON
Parameter Type Required Default Description
name String Yes - Display name in Home Assistant
id String No elero_web_switch Unique component ID
restore_mode Enum No RESTORE_DEFAULT_ON RESTORE_DEFAULT_ON or RESTORE_DEFAULT_OFF

Prerequisites: elero_web must be present.


Output adapter (pick one)

MQTT mode: elero_mqtt

Surfaces devices to Home Assistant via MQTT discovery. Requires the ESPHome mqtt: component.

mqtt:
  broker: 192.168.1.100

elero_mqtt:
  topic_prefix: elero
  discovery_prefix: homeassistant
  device_name: "Elero Gateway"
Parameter Type Required Default Description
topic_prefix String No elero MQTT topic prefix for all device topics
discovery_prefix String No homeassistant Home Assistant MQTT discovery prefix
device_name String No Elero Gateway YAML default for the gateway device name. The web UI can override this at runtime; the override is persisted to NVS.

Notes:

  • Devices added through the web UI appear in HA immediately (no reboot).
  • Save a discovered remote to publish it in Home Assistant.
  • Discovery uses the availability topic and payloads from the ESPHome MQTT client. This includes custom birth and last-will messages. The broker stores the latest light state for clients that reconnect.

Native API mode: elero_nvs

Surfaces devices to Home Assistant via the ESPHome native API. No MQTT broker required.

api:
elero_nvs:

No configuration parameters — including the component enables it.

Notes:

  • At boot, the hub registers enabled covers, lights, and saved groups. Each saved device has a signal-strength sensor. Covers and lights have a state sensor and a fault sensor. A remote shows its last command, channel, and destination.
  • The radio address identifies each cover or light for commands. Devices with the same normalized name show their address in the entity name.
  • ESPHome can't add entities after the initial API connection — adding/removing devices via the UI requires a reboot to surface the change to HA. The UI prompts for this automatically.
  • The hub supports up to 48 saved devices and 16 saved groups.

Complete Example

external_components:
  - source: github://manuschillerdev/esphome-elero

spi:
  clk_pin: GPIO18
  mosi_pin: GPIO23
  miso_pin: GPIO19

elero:
  cs_pin: GPIO5
  gdo0_pin: GPIO26

# Pick one: elero_nvs (native API) or elero_mqtt
elero_nvs:

# Web UI + Backup/Restore
web_server_base:
  port: 80

elero_web:

# Optional: HA toggle for the web UI
switch:
  - platform: elero_web
    name: "Elero Web UI"
    restore_mode: RESTORE_DEFAULT_ON

After flashing, open http://<device-ip>/elero to add devices.

See also: Installation Guide | Backup & Restore | Migration from YAML | README | Example YAML